Sign In | Join Free | My portofva.com |
|
Brand Name : MICH
Model Number : EHTTSTPCP
Certification : ISO9001
Place of Origin : China
MOQ : 1 meter
Price : USD0.5-USD5 per meter
Supply Ability : 10 million meters per year
Delivery Time : in one month
Packaging Details : plywood crates
Dimensions : 0.2"x0.3" (5mm x 8mm) 12 AWG
Dielectric Strength : Over 2000 volts
Property : As per project application
Usage : Thermal Power Plant
Flame Resistance : Good
Wattage : 39Watt/meter
Max. Exposure Temp. (°F) Power Off : 260 or Customized
Voltages : Up to 480
Electric Heat Tracing Technical Solution for Thermal Power Combined Plant is mainly designed for freeze protection for pipelines, tanks, instrumentations etc for the thermal power plant. The principle used to build Combined-cycle Thermal Power Stations consists in an arrangement of heat engines working together from the same source of heat, turning it into mechanical energy that drives electrical generation.
Table 2 Heating Cable Specification (600V Single Conductor)
Cable Code | Diameter | HDPE Diameter | Standard resistance value at +20℃ | Maximum Production Length | Unit weight |
mm | mm | Ω/m | m | kg/km | |
16C1.7 | 8.2 | 10 | 0.0017 | 350 | 366.54 |
16C2.2 | 7.6 | 9.4 | 0.0022 | 380 | 307.77 |
16C2.9 | 7.0 | 8.8 | 0.0029 | 400 | 264.45 |
16C4 | 5.9 | 7.7 | 0.004 | 600 | 190.88 |
16C7 | 5.3 | 7.1 | 0.007 | 600 | 154.08 |
16C11 | 4.9 | 6.7 | 0.011 | 600 | 132.25 |
16C13 | 4.6 | 6.4 | 0.013 | 600 (300)☆ | 125.7 |
16C17 | 4.6 | 6.4 | 0.017 | 600 (300)☆ | 117.16 |
16C21 | 4.6 | 6.4 | 0.021 | 600 (300)☆ | 111.9 |
16C25 | 3.7 | 5.5 | 0.025 | 600 (480)☆ | 68.83 |
16C33 | 3.7 | 5.5 | 0.033 | 600 (480)☆ | 63.76 |
16C40 | 3.4 | 5.2 | 0.04 | 600 (560)☆ | 58.87 |
16C63 | 3.2 | 5 | 0.063 | 600 | 51.47 |
16K80 | 6.8 | 8.6 | 0.08 | 370 (140)☆ | 254.18 |
16K100 | 5.2 | 7 | 0.1 | 450 (240)☆ | 162.11 |
16K140 | 4.9 | 6.7 | 0.14 | 600 (270)☆ | 122.55 |
16K197 | 4.45 | 6.25 | 0.197 | 600 (330)☆ | 111.32 |
16K220 | 4.5 | 6.3 | 0.22 | 600 (330)☆ | 102.89 |
16K315 | 4.3 | 6.1 | 0.315 | 600 (350)☆ | 91.44 |
16K345 | 4.2 | 6.0 | 0.345 | 600 (370)☆ | 85.9 |
16K450 | 4.0 | 5.8 | 0.45 | 600 (400)☆ | 80.73 |
16K630 | 4.0 | 5.8 | 0.63 | 600 (400)☆ | 77.26 |
16K800 | 3.5 | 5.3 | 0.8 | 600 (530)☆ | 61.48 |
16K1250 | 2.8 | 4.6 | 1.25 | 600 | 40.83 |
16K2000 | 2.8 | 4.6 | 2.0 | 600 | 38.96 |
Table 3 Heating Cable Specification (600V Double Conductors)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
26C3.4 | 12.9 | 0.0034 | 150 | 783.76 |
26C4.4 | 12.2 | 0.0044 | 160 | 701.56 |
26C5.8 | 11.3 | 0.0058 | 170 | 606.16 |
26C8.6 | 9.90 | 0.0086 | 180 | 451.43 |
26C11.4 | 9.30 | 0.0114 | 200 | 400.05 |
26C13.8 | 9.00 | 0.0138 | 210 | 375.20 |
26C17.2 | 8.60 | 0.0172 | 220 | 344.90 |
26C23 | 8.00 | 0.023 | 250 | 303.25 |
26C34.4 | 7.50 | 0.0344 | 280 | 269.20 |
26C49.2 | 7.10 | 0.0492 | 300 | 243.84 |
26K240 | 9.90 | 0.24 | 180 | 451.43 |
26K320 | 9.30 | 0.32 | 200 | 400.05 |
26K384 | 9.00 | 0.384 | 210 | 375.20 |
26K480 | 8.60 | 0.48 | 220 | 344.90 |
26K640 | 8.00 | 0.64 | 250 | 303.25 |
26K960 | 7.50 | 0.96 | 280 | 269.20 |
Table 4 Heating Cable Specification (300V Double Cores)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
23C3.4 | 12.0 | 0.0034 | 200 | 708.10 |
23C4.4 | 11.3 | 0.0044 | 220 | 629.07 |
23C5.8 | 10.4 | 0.0058 | 240 | 537.73 |
23C8.6 | 9.00 | 0.0086 | 260 | 392.56 |
23C11.4 | 8.40 | 0.0114 | 280 | 343.89 |
23C13.8 | 8.00 | 0.0138 | 300 | 314.57 |
23C17.2 | 7.60 | 0.0172 | 320 | 286.27 |
23C23 | 7.10 | 0.023 | 340 | 252.98 |
23C34.4 | 6.60 | 0.0344 | 360 | 221.19 |
23C49.2 | 6.20 | 0.0492 | 380 | 197.64 |
23K160 | 10.4 | 0.16 | 220 | 508.37 |
23K240 | 9.00 | 0.24 | 240 | 392.56 |
23K320 | 8.40 | 0.32 | 265 | 343.89 |
23K384 | 8.00 | 0.384 | 280 | 314.57 |
23K480 | 7.70 | 0.48 | 300 | 291.91 |
23K640 | 7.10 | 0.64 | 320 | 252.98 |
23K960 | 6.50 | 0.96 | 350 | 216.11 |
Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);
For the use of 660V voltage occasions, please contact our company professionals;
Mark of (300)☆ is a recommended production length by MICH
Selection Parameters:
Constant Wattage Heating Cable | High Temperature Heating cable | Polyamide/Fiberglass Heating Cable | Harsh Environment Heating Cable | General Purpose Heating Cable |
Available Voltages | 120, 208, 240, 277 & 480 VAC | 120, 208, 240, 277 & 480 VAC | 120, 208, 240, 277 & 480 VAC | 120, 208, 240, 277 & 480 VAC |
Available Wattages
| 4, 8 & 12 watts/ft (13, 26 & 39 watts/m) | 4, 8 & 12 watts/ft (13, 26 & 39 watts/m) | 4, 8 & 12 watts/ft (13, 26 & 39 watts/m) | 3, 5, 8 & 12 watts/ft (10, 16, 26 & 39 watts/m) |
Maximum Exposure Temperature | 500°F (260°C)
| 500°F (260°C)
| 500°F (260°C)
| 400°F (204°C)
|
Nominal Dimensions
| 0.2"x0.3" (5mm x 8mm) 12 AWG
| 0.2"x0.3" (5mm x 8mm) 12 AWG
| 0.2"x0.3" (5mm x 8mm) 12 AWG
| 0.2"x0.3" (5mm x 8mm) 12 AWG |
Resistance to Moisture | Good | Good | Excellent
| Excellent
|
Resistance to Chemicals | Good | Good | Excellent
| Excellent
|
Resistance to Flame | Excellent | Outstanding | Excellent | Outstanding |
Dielectric Strength | Over 2000 volts | Over 2000 volts
| Over 2000 volts | Over 2000 volts |
![]() |
Antifreeze Pipe Tracing Heating Tape Cables For Thermal Power Plant Images |